SR208C 1500W Controller for Split Pressurized Solar Hot Water Heater with Solar Collector
SR208C is used in a split pressurized solar water heater system.
Intelligently controlled by the latest high-performance microcontroller from NXP.
All devices use industrial-grade standards to operate in cold, high-temperature, and humid environments, while using a clock chip for precise timing control.
The controller is LCD type, with beautiful appearance, stable and reliable performance, easy to install, as the most ideal accessory product for split pressure solar water heater.
Max.number of collectors:1
Max.number of storage tanks:1
Max.number of relays:2
Max.number of sensors:3
Max.number of visualization application system: 1
Components | Quantities | Remarks |
Controller | 1pc | SR208C |
Operation manual | 1pc | |
PT1000 sensor | 1pc | ∅ 6*50mm,cable length 1.5mm |
NTC10K | 2pcs | ∅ 6*50mm,cable length 3m |
Accessory bag | 1pc |
Parameter | Value |
Size of Keypad | 178mm×120mm×43mm |
Power supply | AC100~240V 50~60Hz |
Power consumption | < 2.5W |
Measure accurate | ± 2ºC |
Measure scope of collector sensor | -10~220ºC |
Measure scope of tank sensor | 0~110ºC |
Available power of R1 electrical themal trace | < 1A |
T1 | Collector:1*PT1000,≤ 500ºC(Sillicon cable ≤ 280ºC) |
T2,T3 | NTC10K,B=3950,≤ 135ºC(PVC cabke ≤ 105ºC) |
Amblent temperature | -10~50ºC |
Water proof grade | IP41 |
2.2.1 Electromagnetic relay : SR802,can control electric heating of ≤4000W.
Contactor unit of high power: SR802
When user selects electrical heater as back-up device, we recommend using SR802 unit connecting controller and electrical heater.
Technical data of SR802 Dimension: 100mmx100mmx65mm.
Power supply: 180V ~ 264V / AC 50 / 60Hz.
Suitable power: ≤ 4000W.
Available ambient temperature: -10 ~ 50oC Water proof grade: IP43.