• SR258 Solar Controllers for Split Pressurized Solar Water Heating System
  • SR258 Solar Controllers for Split Pressurized Solar Water Heating System
  • SR258 Solar Controllers for Split Pressurized Solar Water Heating System
  • SR258 Solar Controllers for Split Pressurized Solar Water Heating System

SR258 Solar Controllers for Split Pressurized Solar Water Heating System

After-sales Service: Technical Support
Warranty: 1 Year
Condition: New
Certification: API, ISO, CB, CE
Application: Collector Controller, Water Heater Controller, Solar System Controller, Solar Working Station
Rated Voltage: 110-240V
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • 1. Produuct Introduction
  • 2. Technical Parameters
  • 3. Product Installation
Overview

Basic Info.

Model NO.
SR258
Transport Package
Carton
Specification
32X24X7 cm
Origin
Jiangsu, China
HS Code
9032899099

Product Description

SR81/SR868 3000W Solar Controllers for Split Pressurized Solar Water Heater

1. Produuct Introduction

1.1 Overview

  • SR258 is used in a split pressurized solar water heater system.

  • Intelligently controlled by the latest high-performance microcontroller from NXP.

  • All devices use industrial-grade standards to operate in cold, high-temperature, and humid environments, while using a clock chip for precise timing control.

  • The controller is LCD type, with beautiful appearance, stable and reliable performance, easy to install, as the most ideal accessory product for split pressure solar water heater.

SR258 Solar Controllers for Split Pressurized Solar Water Heating System

1.2 Applications Capacity

  • Max.number of collectors:1

  • Max.number of storage tanks:1

  • Max.number of temperature sensor:5

  • Max.number of circulation pump or valve:3

  • Max.number of electronic flowmeter:1

  • Max.number of electromagnetic relays:4

  • Max.number of auxiliary electric heating:1

SR258 Solar Controllers for Split Pressurized Solar Water Heating System1.3 Main functions

  • LCD---display

  • CLK---time setting

  • THET---Timed auxiliary heating

  • CIRC---water-side circulating pump three-time temperature/time control function

  • LOAD---water tank heating setting

  • COL---collector function

  • OCEM---heat collector emergency shutdown function

  • OCCO---collector cooling

  • OCMI---the lowest temperature of the collector

  • OCFR---heat collector antifreeze function

  • PUMP---Water pump control mode (high efficiency pump speed control)

  • COOL---cooling function

  • OSTC---water tank cooling

  • OHDP---heat transfer

  • MAN---manual function

  • BLPR---blocking protection

  • OTDI---high temperature sterilization function

  • FS---Flow monitoring and pump idling protection

  • UNIT---Conversion of Celsius and Fahrenheit

  • BEEP---Buzzer fault alarm function

  • RET---reset

  • PASS---Password setting

  • M.H---manual heating

  • Holiday function

  • Screen Protection

  • Trouble Protection

  • Trouble Checking

1.4 Delivery scope

Components Quantities Remarks
Controller 1pc SR258
Operation manual 1pc  
PT1000 sensor 1pc ∅ 6*50mm,cable length 1.5mm
NTC10K 2pcs ∅ 6*50mm,cable length 3m
Accessory bag 1pc  
Power cord 1pc  
 

2. Technical Parameters

2.1 Technical parameters

Parameter Value
Size of Controller 205mm*150mm*46mm
Power supply AC100~240V 50~60Hz
Power consumption < 2.5W
Measure accurate ± 2ºC
Measure scope of collector sensor -10~220ºC
Measure scope of tank sensor 0~110ºC
Available power of R1 electrical themal trace < 1A
T1 Collector:1*PT1000,≤ 500ºC(Sillicon cable ≤ 280ºC)
T2,T3 NTC10K,B=3950,≤ 135ºC(PVC cabke ≤ 105ºC)
T4,T3 Optional sensor:                            NTC10K,B=3950,≤ 135ºC(PVC cabke ≤ 105ºC)
Amblent temperature -10~50ºC
Water proof grade IP41

2.2 Optional accessories

2.2.1 Electromagnetic relay : SR802,can control electric heating of ≤4000W.

Contactor unit of high power: SR802

 

When user selects electrical heater as back-up device, we recommend using SR802 unit connecting controller and electrical heater.

Technical data of SR802 Dimension: 100mmx100mmx65mm.

Power supply: 180V ~ 264V / AC 50 / 60Hz.

Suitable power: ≤ 4000W.

Available ambient temperature: -10 ~ 50oC Water proof grade: IP43.

SR258 Solar Controllers for Split Pressurized Solar Water Heating System
SR802 Connection Diagram:

SR258 Solar Controllers for Split Pressurized Solar Water Heating System2.2.2 FRT  digital flow meter

SR258 Solar Controllers for Split Pressurized Solar Water Heating System

3. Product Installation

3.1 SR258C Installation diagram

SR258 Solar Controllers for Split Pressurized Solar Water Heating System

SR258 Solar Controllers for Split Pressurized Solar Water Heating SystemSR258 Solar Controllers for Split Pressurized Solar Water Heating System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now